Quick

Quotation

  • Gaia France

  • Logan System 912-12 Automated Transdermal Sampling System

    Features

    • Take samples from 12 bubble free cells at up to 20 sampling time points
    • Open air system, no pressure build up during the tests, no leakage
    • Syringe pump sampling system accuracy to ± 1 %
    • Sampling takes place before media replacement to avoid sample dilution
    • Printer for full report
    The LOGAN SYSTEM 912-12 is designed to save valuable time by delivering precise transdermal samples into HPLC vials automatically. The membrane is mounted between the cell cap (donor) and the cell body (receptor). The membrane is bathed from below by an isotonic saline solution. Temperature is maintained at 37°C by thermostatically controlled water which enters the lower port of the water jacket surrounding the saline solution chamber and circulates out through the upper port. Water is supplied and removed by two (upper and lower) stainless steel manifolds connected to a constant temperature bath.
    Homogenous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet mounted on a timing motor. The cell cap is open to the air, exposing the membrane’s upper surface to ambient conditions. The open cap also allows for a finite dosage application of the compound being studied.
    The SYP Series Syringe Pump Module withdraws and measures sample volumes from transdermal diffusion cells at each time interval. Individual samples are dispensed simultaneously into HPLC vials that are stored in the SCT Series Sample Collectors. To avoid sample dilution, the replacement of media takes place right after each sampling. The lift plate tilts all Franz cells to allow any air bubbles to purge out of the cells while doing the media replacement. This will insure that there will be no air bubbles under the skin/patch; the tilted plate goes back to the horizontal position once the media replacement is complete and continues the test.

    Specifications


    Logan system 912-6 Automated Transdermal Sampling System

    Features

    • Take samples from 6 bubble free cells at up to 20 sampling time points
    • Open air system, no pressure build up during the tests, no leakage
    • Syringe pump sampling system accuracy to ± 1 %
    • Sampling takes place before media replacement to avoid sample dilution
    • Printer for full report
    The LOGAN SYSTEM 912-6 is designed to save valuable time by delivering precise transdermal samples into HPLC vials automatically. The membrane is mounted between the cell cap (donor) and the cell body (receptor). The membrane is bathed from below by an isotonic saline solution. Temperature is maintained at 37°C by thermostatically controlled water which enters the lower port of the water jacket surrounding the saline solution chamber and circulates out through the upper port. Water is supplied and removed by two (upper and lower) stainless steel manifolds connected to a constant temperature bath.
    Homogenous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet mounted on a timing motor. The cell cap is open to the air, exposing the membrane’s upper surface to ambient conditions. The open cap also allows for a finite dosage application of the compound being studied.
    The SYP Series Syringe Pump Module withdraws and measures sample volumes from transdermal diffusion cells at each time interval. Individual samples are dispensed simultaneously into HPLC vials that are stored in the SCT Series Sample Collectors. To avoid sample dilution, the replacement of media takes place right after each sampling. The lift plate tilts all Franz cells to allow any air bubbles to purge out of the cells while doing the media replacement. This will insure that there will be no air bubbles under the skin/patch; the tilted plate goes back to the horizontal position once the media replacement is complete and continues the test.

    Specifications



    Logan FDC-6T Diffusion Cell Drive System

    Features

    • Modular design for system expansion
    • Easily to link up with automated device (optional) for precision sampling from Franz cells with automatic media replacement function
    • Designed to test creams, lotions, ointments, and patches
    • Auto-tilt system to purge air bubbles
    The FDC-6T Transdermal Diffusion Cell Drive Console is remarkably simple to use. Skin is mounted between the cell cap (donor) and the cell body (receptor). The dermis is bathed from below with an isotonic saline solution injected through a port provided for that purpose.
    Temperature is maintained at 37ºC by thermostatically controlled water that enters the lower port of the water jacket and circulates out through an upper port. Warm water is supplied and circulated by two (upper and lower) manifolds that are connected to a constant temperature bath.
    Homogeneous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet and mounted on a timing motor.
    The cell cap is open to the air, exposing the epidermis to the ambient conditions of the laboratory environment. The open cap also allows for finite dose application of study compounds to the epidermis by use of a micropipette or stirring rod.

    Specifications


    Logan FDC-24 Dry-Heat Diffusion Cell System

    Features
    • Available in Franz Cell Versions
    • Two Zone Stirring Control – 12 DHC cells per zone
    • Fast Set Up and Removal of Cells
    • Temperature Control +/- 1 Degree C
    • High Speed Stirring
    • Turn Key Operation
    • Upgradeable to Full Automation
    LOGAN FDC-24 TRANSDERMAL DIFFUSION CELL DRIVE CONSOLE is designed to perform Transdermal Diffusion Testing, up to 24 Franz cells can be tested at the same time. This dry heat system has no need for water heater, the Logan DHC cells are placed on heated blocks. Skin is mounted between the cell cap (donor) and cell body (receptor). The dermis is bathed from below by an isotonic saline solution injected through a port provided for such purpose. Temperature is maintained at 37°C by thermostatically controlled heater block, which all the heat transfers into the glass cells.

    Homogenous distribution of the temperature in the saline bathing solution is accomplished by agitation motion of a Teflon-coated magnetic bar, driven by an external magnet mounted on a timing motor. The cell cap is open to the air, exposing the epidermis to the ambient condition of the laboratory environment. The open cap also allows for finite dose application of study compound to the epidermis micropipette of stirring rod.

    Logan DHC-6T Dry Heat Transdermal System

    Features
    • Heating block design for parallel heating
    • Interchangeable glass cell volumes, no more broken Franz cells
    • Manual or automatic tilting system to purge air bubbles
    • Modular design for system expansion
    • Designed to test creams, lotions, ointments, and patches
    • Built-in sampling device
    • New cleaner look with light covers
    • Patent Pending
    The DHC-6T Dry Heat Transdermal System is remarkably simple to use, the DHBF Cells (Dry Heat Bubble Free Cells) are constructed with molded Teflon donors and precision cut glass bodies. Skin is mounted between the cell cap (donor) and the cell body (receptor). The dermis is bathed from below with an isotonic saline solution injected through the bottom port, which flows thru the upper port to provide contact with no bubbles under the skin.
    Temperature is maintained at 37ºC with a thermostatically controlled heater block. Users can easily insert the DHBF Cells into the cell slots, which will be maintained within ± .3°C of the set temperature. Homogeneous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet, which is mounted on a timing motor.
    The cell cap is open to the air, exposing the epidermis to the ambient conditions of the laboratory environment. The open cap also allows for finite dose application of study compounds to the epidermis by use of a micropipette or stirring rod.

    All the DHBF Cells are installed in a light protection chamber. The samples are taken from the bottom of each DHBF Cell with pre-mounted syringes prior to the media replacement. All the DHBF Cells tilt up while the media replacement is taking place to allow all the bubbles to purge out.

    Specification

    Logan SFDC-6 Transdermal Diffusion Cell Drive System

    Features
    • Modular design for system expansion
    • Set up for 3 sets of Franz Diffusion Cells and 3 sets of Side-by-Side Cells
    • Complete turn key system with temperature control system (water heater/circulator/tank)
    • Designed to test creams, lotions, ointments, and patches
    The SFDC-6 Transdermal Diffusion Cell Drive Console is remarkably simple to operate; the system comes with the water heater and all the accessories. This drive console can operate 3 sets of Franz Diffusion Cells and 3 sets of Side-by-Side Cells. The SS console top is a good working surface for preparing the samples. For the Franz Cell, skin is mounted between the cell cap (donor) and the cell body (receptor). The dermis is bathed from below with an isotonic saline solution injected through a port provided for that purpose. For the Side-by-Side Cells, skin is mounted between 2 cells.
    Temperature is maintained at 32ºC by thermostatically controlled water that enters the water jacket of the cells. Warm water is supplied and circulated by two (upper and lower) manifolds that are connected to a constant temperature bath. Homogeneous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet and mounted on a timing motor.
    The SFDC-6 Drive Console has 2 zones; one is to control the stir of the Franz Cells and the other zone is for the Side-by-Side Cells.

    Specifications



    Logan FDC-6 Transdermal Diffusion Cell Drive System

    Features
    • Modular design for system expansion
    • Easily to link up with automated device (optional) for precision sampling from Franz cells with automatic media replacement function
    • User-friendly program with HPLC online system available
    • Designed to test creams, lotions, ointments, and patches
    The FDC-6 Transdermal Diffusion Cell Drive Console is remarkably simple to use. Skin is mounted between the cell cap (donor) and the cell body (receptor). The dermis is bathed from below with an isotonic saline solution injected through a port provided for that purpose.
    Temperature is maintained at 37ºC by thermostatically controlled water that enters the lower port of the water jacket and circulates out through an upper port. Warm water is supplied and circulated by two (upper and lower) manifolds that are connected to a constant temperature bath.
    Homogeneous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet and mounted on a timing motor.
    The cell cap is open to the air, exposing the epidermis to the ambient conditions of the laboratory environment. The open cap also allows for finite dose application of study compounds to the epidermis by use of a micropipette or stirring rod.


    Logan SDC-6 Transdermal Diffusion Cell Drive System

    Features
    • Modular design for system expansion
    • Set up for 6 sets of Side-by-Side Cells
    • Complete turn key system with Temperature control system (Water Heater / Circulator / Tank)
    The Logan SDC-6 Transdermal Diffusion Cell Drive Console System is composed of:
    • SDC-6 Drive Console
    • Side by Side cell assemblies X 6 sets
    • Heater Circulator
    • Water tank
    The SDC-6 Transdermal Diffusion Cell Drive Console is remarkably simple to use. Skin is mounted between the cell body (donor) and the cell body (receptor). The dermis is bathed from below with an isotonic saline solution injected through a port provided for that purpose.
    Temperature is maintained at 37°C by thermostatically controlled water that enters the lower port of the water jacket and circulates out through an upper port. Warm water supplied and circulated by two (upper and lower) manifolds that are connected to a constant temperature bath.
    Homogeneous distribution of temperature in the saline bathing solution is accomplished by the agitating motion of a Teflon-covered magnetic stirring bar, driven by an external magnet and mounted on a timing motor.
    Specifications
    Power Requirements
    110V—120V 50/60 Hz or 220V—240V 50/60 Hz
    Side-by–Side Cell drive Positions
    6
    Control Zone
    2
    Zone 1: Side-by-Side Cell Positions 1-3
    Zone 2: Side-by-Side Cell Positions 4-6
    Stirring Method
    Teflon coated magnetic bar
    Speed
    50Hz: 500 RMP / 60 Hz:600 RPM
    Heater
    700 watts
    Temperature Range
    25~45°C
    Temperature Accuracy
    1°C


    DNA Collect / Store

    BIOSTAMP - Collecting and storing DNA is a useful material for collecting, shipping and storing of clinical and other critical samples (e.g. forensic samples), in a compact form for long periods of time. 

    30.001 BIOSTAMP 75 stamps 125 €
    30.002 BIOSTAMP 150 stamps 222 €

    Nucleic Acid Remover

    Termi-DNA-Tor is a remover of nucleic acids, bacteria, fungi, and mycoplasma. This product is ideal for cleaning PCR machines, surfaces, pipettes, lab benches, lab equipment, and laminar flow hoods.

    22.001 Termi-DNA-Tor 450 ml 18,00 € 5% 17,10 €
                    21 €
    22.002 Termi-DNA-Tor 2 x 450 ml 30,00 € 5% 28,50 €
                    34 €

    Strip and caps PCR tubes

    4630 8-Strip and Caps 0.2ml PCR Tubes 240 strips and caps
                 456 €
    40.111 4-strip 0.1 ml PCR Tubes, includes strips caps 10.000 tubes
              1 596 €
    40.112 4-strip 0.1 ml PCR Tubes, includes strips caps 1.000 tubes
                 182 €

    PCR Plates

    40.106 96-well PCR Plates, non-skirted 20 plates
    137 €
    40.107 96-well PCR Plates Optical Sealing Film 20 films
    40 €

    Microtubes

    Clear PCR tubes of 0.2 mL volume, with flat caps. These tubes are made of a thin-walled material with excellent thermal transfer capacities which make them better and more reliable for PCR assays

    40.101 0.2 ml thin-walled vial 1.000 vials
    91,20 €
    40.102 1.5 ml with screw cap, sterile 500 vials
    85,50 €
    40.103 1.5 ml vial 2.000 vials
    51,30 €
    40.104 2 ml with screw cap, sterile 500 vials
    96,90 €
    40.105 2 ml vials 1.000 vials
    45,60 €

    Tips

    We offer a variety of tips for different uses. They are RNase/DNase free and come in different formats: Bulk-packed and rack-packed.

    40.011 Yellow tips 20-200 µl 5.000 tips
              68,50 €
    40.012 Clear tips 100 - 1000 µl 5.000 tips
              75,00 €
    40.013 Clear Tips 0.1 - 10 µl 2.000 tips
              40,00 €
    40.035 Rack sterile filter tips for 20 - 200 µl (10 racks, 96 tips/rack) 10 racks
           131,00 €
    40.038 Rack sterile filter tips for 0.1-10ul (10 racks, 96 tips/rack) 10 racks
              85,50 €
    40.039 Rack sterile filter tips for 1.000µl (10 racks, 100 tips/rack) 10 racks
           108,50 €

    Micropipettes

    We offer a portfolio of Mechanical Pipettes of Adjustable Volumes. Our single-channel pipettes are available in eight volume ranges for reliable dispensing of volumes from 0.1 µl to 5 ml. 

    50.201 Pipeta Biotools B10, 0.5-10 µl (increment 0,1 µl) 0.5-10 µl 115 €
    50.202 Pipeta Biotools B50, 5-50 µl (increment 0,5 µl) 5-50 µl 115 €
    50.203 Pipeta Biotools B20, 2-20 µl (increment 0,5 µl) 2-20 µl 115 €
    50.204 Pipeta Biotools B100, 10-100 µl (increment 1 µl) 10-100 µl 115 €
    50.205 Pipeta Biotools B20-200, 20-200 µl (increment 1 µl) 20-200 µl 115 €
    50.206 Pipeta Biotools B50-200, 50-200 µl (increment 1 µl) 50-200 µl 115 €
    50.207 Pipeta Biotools B100-1.000, 100-1.000 µl (increment 5 µl) 100-1.000 µl 115 €
    50.208 Pipeta Biotools B200-1.000, 200-1.000 µl (increment 5 µl) 200-1.000 µl 115 €
    50.209 Pipeta Biotools B1.000-5.000, 1.000-5.000 µl (increment 50 µl) 100-1.000 µl 115 €

    Food Controls



    BIOFOOD - detection and identification of animal species in food/feed


    91.112 BIOFOOD STANDARD kit - Detection of animal species in food 48 rxns 250,00 €
    91.132 BIOFOOD MIXED kit - Simultaneus Identification of animal species in homogeneous food samples 48 rxns 310,00 €


    BIOGENICS - detection and identificacion of GMOs in human & animal food


    91.212 BIOGENICS STD kit - General detection of GMOs in food 48 rxns 315,00 €
    91.222 BIOGENICS RoundUp Ready ® Soya ID kit 48 rxns 225,00 €
    91.232 BIOGENICS Bt-176 MAIZE ID kit 48 rxns 225,00 €
    91.234 BIOGENICS Bt-11 MAIZE ID kit 48 rxns 225,00 €
    91.236 BIOGENICS MON810 MAIZE ID kit 48 rxns 225,00 €
    91.238 BIOGENICS T25 MAIZE ID kit 48 rxns 225,00 €

    DNA controls

    91.001 Fish DNA 500 ng 60,00 €
    91.002 Dog DNA 500 ng 60,00 €
    91.003 Cat DNA 500 ng 60,00 €
    91.004 Pork DNA 500 ng 60,00 €
    91.005 Cow DNA 500 ng 60,00 €
    91.006 Chicken DNA 500 ng 60,00 €
    91.007 Turkey DNA 500 ng 60,00 €
    91.008 Sheep DNA 500 ng 60,00 €
    91.009 Goat DNA 500 ng 60,00 €
    91.010 Rabbit DNA 500 ng 60,00 €
    91.011 Horse DNA 500 ng 60,00 €
    91.014 Human DNA 500 ng 60,00 €
    91.016 Goose DNA 500 ng 60,00 €

    Real time detection PCR kits - Oncology

    AB Analitica

    RQ-105-96* Real quality RS-BCR-ABL p210 One Step 96 tests Consult us
    90066-NGS* Eligene Colorectum PCR Multiplex KRAS, NRAS, BRAF 24 tests Consult us

    Independant internal quality control to be outsourced for infectious

    Complete panels !
    ToRCH G Plus : ToRCH + Parvo B19+ VZV
    ToRCH M Plus : ToRCH + EBV - VCA + EBV – EBNA

    Ready to use tubes directly adaptable ARCHITECT - ABBOTT and LIAISON – DIASORIN automatic machine

    IN0101 Optitrol ToRCH G Plus- negative control - Ready to use 2 x 2,5 ml 159,40 €
    IN0102 Optitrol ToRCH G Plus - poitive control - Ready to use 2 x 2,5 ml 318,60 €
    IN0103 Optitrol ToRCH G Plus - poitive control + negative - Ready to use 4 x 2,5 ml 478,10 €
    IN0104 Optitrol ToRCH G Plus - poitive control + negative - Ready to use 8 x 2,5 ml 956,00 €
    IN0107 Optitrol ToRCH M Plus- negative control - Ready to use 2 x 2,5 ml 159,40 €
    IN0108 Optitrol ToRCH M Plus - positive control - Ready to use 2 x 2,5 ml 456,80 €
    IN0109 Optitrol ToRCH M Plus - positive control + negative - Ready to use 4 x 2,5 ml 637,40 €

    Dropper flask for any automatic machine

    IN0151 Optitrol ToRCH G Plus - negative control – dropper flask 1 x 5 ml 159,40 €
    IN0152 Optitrol ToRCH G Plus - positive control – dropper flask 1 x 5 ml 318,60 €
    IN0153 Optitrol ToRCH G Plus - positive control + negative – flask 2 x 5 ml 478,10 €
    IN0155 Optitrol ToRCH M Plus - negative control – dropper flask 1 x 5 ml 159,40 €
    IN0156 Optitrol ToRCH M Plus - positive control – dropper flask 1 x 5 ml 456,80 €
    IN0157 Optitrol ToRCH M Plus - positive control + negative – dropper flask 2 x 5 ml 573,60 €
    IN0109 Optitrol ToRCH M Plus - positive control + negative – Ready to use 4 x 2,5 ml 637,40 €

    Independent internal control : Mumps, Measles, ParvoB19 and VZV

    IN0302 Optitrol MaPaMuVa M - positive (Codebar tubes) Liaison® 2 x 2,5 ml 467,40 €
    IN0303 Optitrol MaPaMuVa M - positive & negative (Codebar tubes) Liaison® 4 x 2,5 ml 584,20 €

    Independent internal quality control HEV

    IN0701 Optitrol HEV M 2 x 1,5 ml 252,50 €

    Independant internal quality control to be outsourced for urinary cytology

    UA–Cellular® for Iris IQ

    UA–Cellular® for Iris IQ 200 is a cell control of dosed urine that enables to estimate the correctness and accuracy of automated procedures for urinary sediment parameters measurement. This quality control contains stabilized human red and white corpuscules, non-squamous epithelial cells, and cystals in a preservative.
    213396 Levels 1 and 2 - flasks 2 x 120 ml 203,20 €

    UA–Cellular® for UF

    UA-Cellular® for UF (instruments Sysmex) is a cell control of dosed urine that enables to estimate the correctness and accuracy of automated procedures for urinary sediment parameters measurement. This quality control contains red corpuscules, stabilized mammals white corpuscules, stabilized bacterias and urinary sediment in a preservative.
    213465 Levels 1 and 2 - flasks 2 x 45 ml 237,00 €

    Independant internal quality controls to be outsourced for biological liquids

    Cell-Chex Auto

    Dosed total blood control, made for blood cells count in body fluids samples of a patients, in particular pleural liquid, pericardial, peritoneal and synovial.

    Adaptable on CELL-DYN 3200 Abbott; the Sapphire® and the Ruby®; LH 750/LH 755, LH 780 of Beckman Coulter® and UniCel® DxH 800; XE-2100™, XE-5000™, XT-2000i™, XT-1800i™ and XT-4000i™ of Sysmex®
    200065 Cell-Chex Auto: Level 2 and 3 - percutable plastic tubes 2 x 3,0 ml 184,60 €
    200066 Cell-Chex Auto: Level 1, 2 and 3 - percutable plastic tubes 3 x 3,0 ml 277,50 €

    Cell-Chex

    CQ for total cellular count made manually with a hemocytometer to validate the quantification of white and red corpuscules in cerebrospinal liquid and the body fluids samples of a patient, in particular pleural liquid, pericardial, peritoneal and synovial.

    212431 Cell-Chex : L1-UC, L1-CC, L2 – Glass flasks 3 x 2 ml 138,10 €
    212429 Cell-Chex : L1-CC – Glass flasks 2 x 2 ml 112,10 €
    212420 Cell-Chex : L1-UC, L2 – Glass flasks 4 x 2 ml 199,70 €

    Hybridization

    Hybridization reagents

    GHYFOR00-01 Formamide 500 ml 28,30 €
    GHYFOR01-01 Deionised formamide 500 ml 49,50 €
    GHYSDS02-01 SDS solution at 20% 500 ml 41,70 €

    Hybridization buffers

    GHYSSC00-07 SSC buffer 20X 1 liter 48,20 €
    GHYSSC00-08 SSC buffer 20X 5 liters 57,80 €
    GHYSSP00-07 SSPE buffer 20X 1 liter 63,30 €
    GHYSSP00-08 SSPE buffer 20X 5 liters 104,50 €

    Immunology AbCys - PSA-NCAM

    Our antibody Anti - PSA - NCAM clone 2-2B is widely published in the most prestigious reviews.
    This monoclonal antibody is valid for immunohistochemistry, immunofluorescence, flow cytometry and Elisa.
    • Excellent marker neural progenitors,
    • Functionality marker of Pancreas beta cells.

    ABC0019 Anti-PSA-NCAM antibody (polysialic acid NCAM) clone 2-2B 50 μl 332,06 €
    ABC0027B ELISA dosage kit PSA-NCAM 96 wells 650,09 €
    ABC0026 Anti-NCAM antibody 200 μl 277,64 €
    ABC0020 Endo-N (Endo-neuraminidase-N) 50 μl (35 U) 405,36 €
    ABC0101 Anti-Glu-Tubulin antibody 300 μg 816,67 €
    ABC0102 Anti-Tubulin Delta-2 antibody 300 μg 372,04 €
    VMA377 Anti-NeuN clone A60 500 μg 455,66 €
    VPA2253 Anti-Doublecortin DCX 50 μl 597,06 €
    VPA152 Anti-Thyrosine Hydroxylase 100 μl 609,50 €
    ABC117-7513 Anti-Brdu clone BU1/75 (ICR1) 500 μg 1 274,64 €
    ABC117-7516 Anti-Brdu clone BU1/75 (ICR1) 250 μg 650,09 €

    Cloning

    Stained substrates

    GCGIPT00-6W* IPTG 1 g 34,50 €
    GCGIPT00-6X* IPTG 5 g 142,60 €
    GCGXGA00-6U* X-GAL 500 mg 153,10 €

    Antibiotics

    GABAMP00-6Z Ampicillin sodim salt 25 g 96,30 €
    GABKAN00-6Z Kanamycine SULFATE 25 g 133,40 €
    GABTET00-6Z Tetracycline hydrochloride 25 g 28,60 €
    GABCLR00-6Z Chloramphenicol 30,70 €

    © powered by Gaia France - SAS registered at Nanterre Commercial Court - rue Louis Pouey, 92800 Puteaux, France. All right reserved.